Panel & Breaker Upgrades

Panelboard and load-center change-outs, branch and feeder breaker replacement, and trip testing on breakers already in service. Where a panel brand is obsolete and no listed replacement breaker exists, we change out the interior or the whole assembly rather than hunting salvage parts.

/ Scope

What's typically included

  • Panelboard and load-center change-outs, 100A–800A
  • Branch, feeder, and main breaker replacement
  • Trip-unit testing by primary or secondary injection
  • Ground-fault protection testing per NEC 230.95(C)
  • Obsolete panel replacement — Federal Pacific, Zinsco, Challenger
  • Sub-panel install and typed circuit directories
Self-perform
Our own crew on the install — not a sub.
Stamped drawings
FL PE on staff and consulting.
Closeout package
As-builts, test reports, O&M manuals.
Service Dispatch · Jacksonville, FL

Talk to an electrician.

Describe the scope — panel, switchgear, generator, lighting, EV — and we tell you what it takes and when we can be on site.

  • Office Mon–Fri 7AM–5PM · Service Dispatch
  • FL Unlimited Electrical · EC13007649
  • Duval County · St. Johns County · Clay County · Nassau County
/ Why people call

What it usually
looks like first.

Any one of these is reason enough to get us on site. Describe what you're seeing — we'll tell you on the phone whether it needs a truck today or a scheduled visit.

01

A breaker won't reset — or trips again as soon as it does

Either the circuit is faulted or the breaker's mechanism has aged out. Both need a meter on the load before anyone buys a part.

02

Discolored breaker, warm dead-front, or a smell

Heat at a breaker is a loose lug or a failing device. This is the one item on the list we do not schedule for next week.

03

No spare poles left in the panel

Tandem breakers and double-tapped lugs where a sub-panel belongs. Every new load makes the next one harder and the labels less true.

04

Your panel brand is discontinued

Federal Pacific Stab-Lok, Zinsco, Challenger: no listed replacement breaker made today fits, and carriers increasingly write it up at renewal.

05

Ground-fault protection has never been performance-tested

NEC 230.95(C) calls for a performance test when GFP is first installed, and NFPA 70B puts it on a schedule after that. On 480Y/277V services 1000A and up, nobody finds out it failed until it fails.

06

The panel directory is twenty years out of date

During an outage, the time spent finding the right breaker is the outage. A verified directory is an hour of work that pays back once.

/ How the work runs

Four steps, in this order.

01

Read the load before specifying the panel

A recording ammeter on the feeder, or the utility's 12-month demand data under NEC 220.87. The new panel gets sized from measured load, not a rule of thumb.

02

Permit and the outage window

Permit to the AHJ, and where the work touches the service entrance, an outage window and re-energization sequence agreed with JEA, FPL, or Clay Electric.

03

Change-out or interior swap

New panelboard, or a new interior in the existing enclosure where code and the listing allow it. Lugs torqued to the manufacturer's value, with the value written down.

04

Test, label, and hand over

Trip test where the gear calls for one, GFP performance test where the service requires it, typed directory, arc-flash label refreshed to what's actually installed.

WhereDuval County · St. Johns County · Clay County · Nassau County — dispatched from Jacksonville.Service area