/ Preventive Maintenance Contracts · Jacksonville, FL

Catch it
before it trips.

Electrical preventive maintenance contracts with IR thermographic scanning, torque audits, ground-resistance testing, and a written report after every visit. Annual, semi-annual, and quarterly programs.

40+
Active maintenance contracts
IR + torque
Every visit, every panel
Written report
Photos after every visit
NETA-aligned
Maintenance test standard
/ Program tiers

Three programs.
One standard.

1× per year
Annual
  • IR thermographic scan — all switchgear and panels
  • Torque audit — main lugs and service connections
  • Visual inspection — all distribution equipment
  • Written report with photos
Best for
Small retail and office — under 400A service
2× per year
Semi-Annual
  • All Annual items
  • Ground-resistance testing
  • Insulation-resistance testing on feeders
  • Panel cleaning and dust removal
  • Arc-flash label audit and update
Best for
Medical, hospitality, and industrial — 400A–2000A
4× per year
Quarterly
  • All Semi-Annual items
  • Generator runtime test and battery check
  • UPS and transfer switch inspection
  • Monthly critical-equipment check-in (remote)
  • Priority 60-min emergency dispatch
Best for
Data centers, hospitals, mission-critical — 2000A+
/ What we actually find

Issues caught
before failure.

Across 200+ commercial IR scans, these are the issues we catch on maintenance visits — before they become outages or fires.

Hot lugs and connections

High-resistance connections generate heat long before they fail. IR catches them at 5–15°C delta T, well before the 40°C NEMA threshold.

Loose bus connections

Thermal expansion cycling loosens bolted bus joints over time. Torque audit finds these without IR — a $40 fix before a $4,000 repair.

Failing breakers

Breakers with internal heating from worn contacts show up clearly on an IR scan. We flag before they trip under load.

Ground-fault paths

Ground-resistance testing finds deteriorated ground electrodes and broken equipment grounds — invisible without testing.

/ The report

Inspector-ready
documentation.

Every visit includes a written report with findings, photos, temperature deltas, and a priority-ranked repair list. The kind of document you can show your insurance carrier.

  • Thermal images with temperature scale and delta-T readings
  • Torque audit log — each lug, bolt, and connection checked
  • Ground-resistance test readings (three-point fall-of-potential)
  • Insulation-resistance test log per NEC and NETA standards
  • Priority-ranked repair list — critical, advisory, and note
  • Panel directory verification and labeling notes
  • Arc-flash label audit — flag outdated or missing labels
  • Generator or UPS findings (if in scope)
"Annual switchgear PM with IR scans caught a hot lug we'd have lost a transformer on. Their report is the kind of paperwork I show ownership without explaining."
S. Whitcombe, Hotel GM
Ponte Vedra Beach, FL
/ Get a maintenance quote

Tell us your facility.
We'll build a program.

Square footage, service size, number of panels, and whether you have a generator. We'll match you to the right program and come back with a number.

Emergency dispatch
(904) 555-0162
Book Online · 24/7 Dispatch

Schedule service in minutes.

Pick a time that works — no phone tag, no hold music. We confirm every booking within the hour.

  • Available 24 / 7 including weekends
  • Confirmation within 60 minutes
  • Licensed & insured · Jacksonville FL
No credit card required · Confirm in minutes