/ Preventive Maintenance Contracts · Jacksonville, FL

Preventive
Maintenance.

Electrical preventive maintenance contracts with IR thermographic scanning, torque audits, ground-resistance testing, and a written report after every visit. Annual, semi-annual, and quarterly programs.

40+
Active maintenance contracts
IR + torque
Every visit, every panel
Written report
Photos after every visit
NETA-aligned
Maintenance test standard
/ Why people call

The year you stop
paying for surprises.

Nobody signs a maintenance agreement out of enthusiasm. It usually follows one of these — an outage, an inspection, or an electrical room somebody inherited with no paperwork at all.

01

Two unplanned outages in the same year

The second one is the signal. Unplanned downtime almost always traces back to a connection, a breaker, or a ground that a scheduled visit would have found.

02

Your carrier or the AHJ asked for records

Insurers increasingly want an IR scan on file, and inspectors want test records. Neither can be produced retroactively.

03

Arc-flash labels expired, or don't match the gear

Labels drift out of date every time the system changes. NFPA 70E asks for a review at least every five years, and a wrong label is a hazard in its own right.

04

Nobody has torque records for the gear

Loose connections are the single most common thermal finding in a scan. Without a torque audit, the only record is the heat itself.

05

A new facility manager inherited undocumented equipment

No asset list, no single-line, no service history. The first visit builds all three, and every visit after that refers to the same list.

/ Program tiers

Three programs.
One standard.

Quarterly
Essential
  • IR thermographic scan of all switchgear and panels
  • Torque audit on lugs and connections
  • Written report with photos and prioritized findings
Best for
Healthcare, data centers, and mission-critical facilities
Semi-annual
Standard
  • Semi-annual IR scan and torque audit
  • Ground-resistance and insulation testing
  • Generator load-bank and ATS verification
Best for
Multifamily, hospitality, and large retail
Annual
Basic
  • Annual IR scan and torque audit
  • Panel cleaning and arc-flash label refresh
  • Written report with code-compliance summary
Best for
Office buildings, small retail, and houses of worship
/ What we actually find

Issues caught
before failure.

Across 200+ commercial IR scans, these are the issues we catch on maintenance visits — before they become outages or fires.

Hot lugs and connections

High-resistance connections generate heat long before they fail. IR catches them at 5–15°C delta T, well before the 40°C NEMA threshold.

Loose bus connections

Thermal expansion cycling loosens bolted bus joints over time. Torque audit finds these without IR — a $40 fix before a $4,000 repair.

Failing breakers

Breakers with internal heating from worn contacts show up clearly on an IR scan. We flag before they trip under load.

Ground-fault paths

Ground-resistance testing finds deteriorated ground electrodes and broken equipment grounds — invisible without testing.

/ How the work runs

Four steps, every year,
against the same asset list.

01

Inventory the assets once

Every panel, switchboard, ATS, and transformer numbered and photographed on the first visit. Every visit after that refers to the same list, so findings can be compared year over year.

02

Scope the year, not the visit

Which assets get scanned under load, which need a de-energized window, and when the building can actually give up that window. Agreed once, calendared for the year.

03

Scan under load, test in the window

IR scans happen with the building running — that is the only time a loose connection shows itself. Torque, cleaning, and electrical testing happen in the scheduled outage.

04

Report, rank, and book the next date

Findings ranked by severity with photos and readings attached, repairs quoted separately from the contract, and the next visit on the calendar before we leave.

/ The report

Inspector-ready
documentation.

Every visit includes a written report with findings, photos, temperature deltas, and a priority-ranked repair list. The kind of document you can show your insurance carrier.

  • Thermal images with temperature scale and delta-T readings
  • Torque audit log — each lug, bolt, and connection checked
  • Ground-resistance test readings (three-point fall-of-potential)
  • Insulation-resistance test log per NEC and NETA standards
  • Priority-ranked repair list — critical, advisory, and note
  • Panel directory verification and labeling notes
  • Arc-flash label audit — flag outdated or missing labels
  • Generator or UPS findings (if in scope)
Annual switchgear PM with IR scans caught a hot lug we'd have lost a transformer on. Their report is the kind of paperwork I show ownership without explaining.
S. Whitcombe, Hotel GM
Ponte Vedra Beach, FL
/ Get a maintenance quote

Tell us your facility.We'll build a program.

Square footage, occupancy type, and current contract status (if any). We come back with a tiered proposal and a sample report from a similar facility.

Service dispatch
(904) 217-2520
Service Dispatch · Jacksonville, FL

Talk to an electrician.

Describe the scope — panel, switchgear, generator, lighting, EV — and we tell you what it takes and when we can be on site.