Industrial
Electrical.
Industrial electrical from 480V distribution and motor control centers through arc-flash labeling and preventive maintenance. Warehouses, distribution centers, cold storage, and light manufacturing in Duval, Clay, and Nassau counties.
What we install
and maintain.
Motor Control Centers (MCCs)
Service entrance to 4000A, switchgear and motor control center install, bus duct, and distribution panelboards for heavy industrial loads.
VFD / Soft Starter Install
New MCC install and bucket replacement, VFD wiring and startup, soft-starter circuits, and control transformer sizing.
Transformer Install & Service
NFPA 70E-compliant arc-flash study, labeling, and PPE boundary calculations. We deliver the study and hang the labels ourselves.
Hazardous Location Wiring
Ground-resistance testing, insulation-resistance testing, power-factor correction, and harmonic analysis for production-critical equipment.
Power Quality Analysis
Harmonic analysis, voltage-dip studies, and power-factor correction install for process plants and data-heavy facilities.
High-Bay LED Lighting
High-bay LED retrofit with controls — occupancy sensing, photocell, and dimming for warehouses and manufacturing floors.
From service entrance to equipment disconnects.
We install the full electrical scope on industrial build-outs and handle rapid repair and annual maintenance on existing facilities.
- 01Service Entrance & Switchgear
800A–4000A service entrance upgrades with utility-coordinated outages. Switchgear maintenance, breaker replacement, and arc-flash labeling.
- 02Distribution & MCC
480V distribution panelboards, motor control center install and bucket replacement, VFD circuits, and transformer sizing.
- 03Production Circuits & Lighting
Dedicated equipment circuits, compressed-air and compressor circuits, high-bay LED lighting with controls, and hazardous-location wiring.
- 04Testing & Commissioning
Ground-resistance testing, insulation-resistance testing, load-bank testing on standby systems, and arc-flash study with labeled panels.
NFPA 70E.
Arc-flash.
OSHA ready.
IEEE 1584-compliant incident energy analysis. We deliver the study in a format your safety team can use, and hang the labels ourselves.
Arc-flash and shock-hazard boundaries calculated per NFPA 70E. Labels include incident energy in cal/cm² and required PPE level.
Written LOTO procedures for major equipment as part of our commissioning package. OSHA 29 CFR 1910.147 compliant.
Switchgear cleaning, torque audits, IR scans, and insulation-resistance testing on an annual schedule. Written report after every visit.
Send us the one-line.We'll take it from there.
Service voltage, motor count, and any hazardous-location classification on site. We come back with arc-flash assessment scope and a rough number.
Schedule service in minutes.
Pick a time that works — no phone tag, no hold music. We confirm every booking within the hour.
- Available 7 days a week including weekends
- Confirmation within 60 minutes
- Licensed & insured · Jacksonville FL